GENERAL
NOTES
ALL CONSTRUCTION TO MEET
OR EXCEED ALL LOCAL, STATE, & NATIONAL BUILDING CODES
HEATING NOTES
HEATING BY OIL FIRED BOILER OR AS SELECTED BY THE OWNER
PLUMBING
NOTES
PIPE W/ ‘L’ OR
‘K’ COPPER PIPE FOR ALL WATER SUPPLY LINES 3/4" DIA
MAIN w/ 1/2" BRANCH LINES
GC TO PROVIDE ISOLATION VALVES PER OWNERS SPECIFICATION |
ELECTRICAL
NOTES
OUTLETS IN BATHROOMS,
KITCHEN, & LAUNDRY TO BE GFI OUTLETS
EXTERIOR OUTLETS TO BE WATERPROOF GFI OUTLETS
110 VOLT OUTLETS ARE TO BE LOCATED @ 10’ OC MAX FOR ALL INTERIOR
ROOMS
ALL ROOMS ARE TO HAVE A SWITCHED OUTLET OR SWITCHED LIGHT FIXTURE
INSTALL INTERCONNECTED FIRE & SMOKE DETECTOR SYSTEM IN BEDROOMS,
HALL, LIVING & KITCHEN
DOOR NOTES
ALL INTERIOR
EGRESS DOORS ARE TO BE A MINIMUM OF 2’-8" WIDE AND 6’-8"
HIGH
ALL EXTERIOR EGRESS DOORS ARE TO BE A MINIMUM OF 3’-0" WIDE
AND 6’-8" HIGH |
STAIR
AND RAILING NOTES
ALL STRAIGHT
RUN STAIRS ARE TO HAVE TREADS W/ A MINIMUM WIDTH OF 9" W/ 1
1/8" NOSINGS AND RISERS W/ A MAXIMUM HEIGHT OF 8 1/4"
ALL STAIR, LANDING, AND BALCONY RAILINGS ARE TO BE 36" HIGH
ABOVE NOSINGS, LANDINGS, OR FLOORS
FREE STANDING RAILINGS
ARE TO HAVE BALUSTER AT 4" OC MAX
ALL STAIRS ARE TO HAVE A MINIMUM OF 6’-8" CLEAR HEIGHT ABOVE
STAIR NOSINGS
FIRE SEPARATION NOTE
THE GARAGE IS
TO BE SEPARATED FROM ALL ADJACENT LIVING SPACES BY A ONE HOUR FIRE
RATED ASSEMBLY |