FIRST
FLOOR FRAMING NOTES
DEFLECTION OF THE
FIRST FLOOR DECK IS TO BE LESS THAN 1/360TH OF THE SPAN WITH A DEAD
LOAD OF 15 PSF AND A LIVE LOAD OF 40 PSF
BRIDGE FLOOR JOISTS AT 8’—0" MINIMUM
FINISHED DECK TO BE FLAT AND LEVEL TO WITHIN A TOLERANCE OF 1/8"
INSTALL SOLID BLOCKING BELOW STRUCTURAL COLUMNS AT ALL LOCATIONS
COORDINATE COLUMN AND STAIR LOCATIONS WITH FRAME DRAWINGS
TJI’S, RIM BOARDS & LVL’S AS MANUFACTURED BY TRUSS JOIST OR EQUIVALENT
INSTALL BEAM POCKETS AS
REQUIRED BY FIRST FLOOR FRAMING |
FOUNDATION
NOTES
ALL
DIMENSIONS TO BE VERIFIED IN FIELD BY OTHERS
FOOTINGS TO BEAR ON UNDISTURBED SOIL WITH A BEARING CAPACITY OF
2500 PSF
TOP OF FOOTING TO BE AT 48" MINIMUM BELOW GRADE
THE LOCATIONS AND HEIGHTS
OF STEPPING IN THE FOUNDATION WALL DEPENDS ON THE EXISTING GRADE
BASEMENT DOOR AND WINDOWS NOT TO BE LOCATED UNDER STRUCTURAL POST
INSTALL BEAM POCKETS AS REQUIRED BY FIRST FLOOR FRAMING
THE MUDROOM FOUNDATION
IS SIZED FOR A PANEL WALL ENCLOSURE |